Dryer Bosch MAXX7 sensitive does not turn-on
Bosch MAXX7 Sensitive
E-number: WTE843A2
Description of failure
The dryer does not turn-on at all or turns-off automatically during usage.
Failure investivation
The internal power supply, a flyback topology, has died. There is no stable output voltage of the flyback converter. Measuring the internal body-diode of the integrated switch shows a short. Things to replace:
Flyback controller:
TNY 266PN
2x Output capacitors
22 µF
,105 °C
After replacing the broken components, the dryer works totally fine.